acute-logo

RA-915 F Field Mercury Analyser with Direct Thermal Decomposition

RA-915F

Achieve accurate, reliable and cost-effective mercury measurements with the RA-915 F Field Mercury Analyser—designed for direct thermal decomposition across the broadest range of sample matrices. This compact three-unit system analyzes complex samples ‘as is’ without pre-treatment, combining atomic absorption spectrometry with programmable thermal release for interference-free results. Ideal for environmental field surveys, mine site monitoring, petroleum testing and rapid contamination assessment. The real-time feedback system handles soils, water, crude oil, coal and biological tissues with ppb-level sensitivity in 1–5 minute cycles. No wet chemistry, compressed gases or gold traps needed—air carrier operation reduces complexity and field deployment costs. The modular design fits mobile laboratories and remote testing stations. Fast warm-up and zero memory effect enable high-throughput screening. Universal power and lightweight construction support generator or battery operation in any location. Share your field testing requirements—our team will configure the RA-915 F with sample boats and methods for your on-site mercury analysis program.

  • Direct thermal decomposition—no digestion, reagents or wet chemistry required
  • Atomic absorption spectrometry at 254 nm with Zeeman background correction
  • Ultra-low detection limit: 0.5 ppb (μg/kg) for most solid matrices
  • Wide dynamic range: 0 – 200,000 ppb (μg/kg) spanning 5+ orders of magnitude
  • Real-time feedback system for sample decomposition control eliminates matrix interferences
  • Sample boat capacity: 1,000/2,000 mg (solids) or 500/1,000 µL (liquids)
  • Rapid analysis: 1–5 minutes per sample from injection to result
  • Fast warm-up: ready for analysis in 40 minutes or less
  • Programmable furnace (150–800 °C) for optimal decomposition and thermospeciation studies
  • Air as carrier gas—no compressed oxygen or argon required for safe field operation
  • No gold trap pre-concentration increases analysis speed and reduces complexity
  • Zero memory effect—analyze low-concentration samples immediately after high concentrations
  • Universal power supply: 100–240 VAC, 50–60 Hz for global field deployment
  • Low power consumption: maximum 700 W for battery or generator compatibility
  • Compact modular design: spectrometer, thermal unit and power supply for mobile labs
  • Lightweight construction: 21.5 kg total weight for field portability
Specification Details
Measurement Principle Direct thermal decomposition with atomic absorption at 254 nm and Zeeman correction
Detection Limit 0.5 ppb (μg/kg)
Measurement Range 0 – 200,000 ppb (μg/kg)
Sample Boat Capacity 1,000/2,000 mg or 500/1,000 µL
Analysis Time 1 – 5 min
Warm-up Time ≤40 min
Temperature Range 150 – 800 °C (atomizer and analytical cell)
Power Supply 100 – 240 VAC, 50 – 60 Hz
Power Consumption Max. 700 W
Dimensions (W×D×H) 175×110×235 mm (spectrometer)<br>430×340×135 mm (thermal unit)<br>400×280×135 mm (power supply)
Weight 21.5 kg (complete system)

GET A QUOTE